Description
Summary
Dimensions mm
998 x 345 x 212
Capacity W.T.B
18000
Basic Technology
60% Energy Saving with 30% Faster Cooling
Additional Specifications
Smart Connectivity (Wi-Fi)
Off
General Specifications
Cooling Capacity (Min ~ Rated ~ Max)
1.08 ~ 5.28 ~ 5.36 kW
3685 ~ 18000 ~ 18300 BTU/h
Heating Capacity (Min ~ Rated ~ Max)
1.08 ~ 5.71 ~ 6.10 kW
3685 ~ 19480 ~ 20800 BTU/h
Power Input – Cooling (Min ~ Rated ~ Max)
238 ~ 1,650 ~ 1,900 W
Power Input – Heating (Min ~ Rated ~ Max)
238 ~ 1,650 ~ 1,800 W
Operating Current – Cooling (Min ~ Rated ~ Max)
1.10 ~ 7.50 ~ 9.10 A
Operating Current – Heating (Min ~ Rated ~ Max)
1.10 ~ 7.40 ~ 8.52 A
EER
3.20 W/W
10.91 (Btu/h)/W
WEER
17.02 (Btu/h)/W
COP
3.46 W/W
11.81 (Btu/h)/W
Cooling/Heating (Additional Charge)
A++++ / –
Power Supply
1, 220, 50 (Φ/V/Hz)
Available Voltage Range
187 ~ 253 V
Power Factor – Cooling
95%
Power Factor – Heating
95%
Unit Indoor – Air flow rate (cooling, max/high/medium/litre)
19.3/13.5/12/9 m³/min
Indoor unit – Air flow rate (heating, max/H/M/L)
20/14/13/9.5 m³/min
Indoor unit – Sound pressure level (cooling, H/M/L/SL)
-/44/39/34/31 dB(A)
Indoor unit – Sound pressure level (heating, H/M/L)
-/44/39/34 dB(A)
Indoor unit – Dimensions (W x H x D) – Net
210x345x998 mm
Indoor unit – Dimensions (W x H x D) – Shipping
278x424x1053 mm
Indoor unit – Weight (net)
12.8 kg
Indoor unit – Weight (shipping)
15.0 kg
Indoor unit – Colour code Outdoor
Munsell 7.5PB 0.2/20 (RAL 9005)
Outdoor unit – Air flow rate (max)
38.0 m³/min
Outdoor unit – Fan motor speed (cooling, min ~ max)
200 ~ 900 rpm
Outdoor unit – Fan motor speed (heating, min ~ max)
200 ~ 900 rpm
Outdoor unit – Sound pressure level (cooling, rated)
54 dB(A)
Outdoor unit – Sound pressure level (heating, rated)
56 dB(A)
Outdoor unit – Dimensions (W x H x D) – Net
288x545x770 mm
Outdoor unit – Dimensions (W x H x D) – Shipping
392x599x919 mm
Outdoor unit – Weight (net)
32.5 kg
Outdoor unit – Weight (shipping)
38.0 kg
Outdoor unit – Max. For fuse
15 A
Outdoor unit – Outdoor colour code
Munsell 9.54Y 8.34/1.31 (RAL 9001)
Outdoor unit – Operating range (cooling)
18 ~ 48 °C DB
Outdoor unit – Operating range (heating)
-5 ~ 24 °C DB
-5 ~ 18 °C WB
Circuit breaker
20 A
Power supply cable
3 × 1.5 (number × mm²)
Power supply unit
Outdoor
Power and communication cable
4 × 0.75 (number × mm²)
Pipes – Volume (liquid)
6.35 mm diameter
Pipes – Volume (gas)
12.7 mm diameter
Pipes – Connection method (indoor unit/outdoor unit)
Flare
Drain hose size – indoor unit, outdoor unit
21.5, 16.0 mm
Between indoor and outdoor unit – Pipe length (max (minimum/standard/maximum)
3/7.5/20 m
Between indoor and outdoor unit – Pipe length (without charge)
3.5 m
Between indoor and outdoor unit – Max height difference
10 m
Between indoor and outdoor unit – Thermal insulation of pipe connection
Both liquid and gas pipes
Refrigerant – Type
R410A
Refrigerant – Precharge
1230 g
Refrigerant – Additional charge
20 g/m
Refrigerant – Control
Capillary
Refrigerant – Global Warming Potential
2087.5
Refrigerant – tCO2e
2.568
Product Type
Art cool