Description
Dual Inverter Compressor™ with 10-Year Warranty
LG’s Dual Inverter Compressor™ solves the problems of improper and ineffective noise, enabling the air conditioner to cool faster, last longer and run quieter. With a 10-year warranty on the compressor, users can enjoy the benefits of LG air conditioner for a longer period of time.
Dual Inverter Compressor™1
Dual Inverter Compressor™
The compressor operates at a high rotation frequency to save more energy and has a faster cooling range.
10-Year Warranty
The product has received TUV Rheinland’s 10-year product life cycle validation
TUV Rheinland
TUV Rheinland, Verification of Cooling Speed and Energy Saving (US-W242Kxy0/TS-H2465DA0)
Energy Saving
The inverter compressor constantly adjusts the compressor speed to maintain desired temperature levels. Furthermore, the Dual Inverter Compressor™ with an energy-saving operating range saves more energy than a conventional compressor.
Fast Cooling
LG air conditioners start cooling the air quickly using their high-speed cooling range thanks to the Dual Inverter Compressor™, thus blowing air farther and cooling spaces faster.
Simple and Slim Design with Hidden Display
LG’s slim and sophisticated design makes it easy to install and conveniently clean with the EZ Slide Filter. Moreover, the large hidden display is perfect for checking your energy display conveniently.
Low Noise
LG air conditioners operate at low sound levels, thanks to LG’s unique tilt fan and Dual Inverter Compressor™ that eliminate unnecessary noise and allow for smooth operation.
Quick and Easy Installation
LG air conditioners are designed for easier and more efficient installation, regardless of the surroundings and the number of people involved in the installation process. By reducing the labor and time required for installation, it is now possible to install more air conditioners in more homes in a shorter period of time.
6-Step Vertical Slot Control
Users can choose the vane direction from 6 preset positions to precisely meet the airflow in the direction you want.
Dual Protection Filter
The dual protection filter captures dust and bacteria as small as 10 microns.
Automatic Cleaning
The comprehensive auto-cooling function prevents the formation of bacteria and fungi on the heat exchanger, thus providing a more comfortable and pleasant environment for the user.
Gold Fin™
Gold Fin™ ensures that the surface is more resistant to corrosion and enhances the durability of the heat exchanger for a much longer period.
Jet Dry Technology
Jet Dry Technology prioritizes the removal of moisture from areas with high humidity levels to keep the air in your room dry and fresh.
Fast Heating
The four-way automatic swing adjusts the airflow based on the surrounding environment, allowing warm air to be distributed throughout the living areas and enabling fast heating.
Summary
General Specifications
Cooling Capacity (Min ~ Rated ~ Max)
0.88 ~ 3.52 ~ 3.87 kW
3,000 ~ 12,000 ~ 13,200 BTU/h
Heating Capacity (Min ~ Rated ~ Max)
0.88 ~ 3.52 ~ 4.04 kW
3,000 ~ 12,000 ~ 13,800 BTU/h
Power Input – Cooling (Min ~ Rated ~ Max)
140 ~ 1,150 ~ 1,300 W
Power Input – Heating (Min ~ Rated ~ Max)
140 ~ 975 ~ 1,350 W
Running Current – Cooling (Min ~ Rated ~ Max)
0.80 ~ 6.60 ~ 7.20 A
Running Current – Heating (Min ~ Rated ~ Max)
0.80 ~ 5.50 ~ 7.20 A
EER
3.06 W/W
10.43 (BTU/h)/W
WEER
16.68 (BTU/h)/W
Energy Label Grade – Cooling
A+++
COP
3.61 W/W
12.31 (BTU/h)/W
Cooling/Heating (Extra Charge)
A++++ / –
Power Supply
1, 220, 50 (Φ/V/Hz)
Available Voltage Range
187 ~ 253 V
Power Factor – Cooling
80%
Power Factor – Heating
80%
Dehumidification
0.80 L/h
Indoor Unit – Air Flow Rate (Cooling, Max/High/Medium/L)
12.5/9.3/7.2/2.7 m³/min
Indoor Unit – Air flow rate (heating, Max/H/M/L)
13/10/7/5.5 m³/min
Indoor unit – Sound pressure level (cooling, Max/H/M/L/SL)
-/41/36/28/21 dB(A)
Indoor unit – Sound pressure level (heating, Max/H/M/L/SL)
-/47/42/34 dB(A)
Indoor unit – Dimensions (W x H x D) – Net
189x308x837 mm
Indoor unit – Dimensions (W x H x D) – Shipping
253x385x882 mm
Indoor unit – Weight (net)
9.0 kg
Indoor unit – Weight (shipped)
11.0 kg
Indoor unit – Outdoor colour code
Munsell 7.5BG 10/2 (RAL 9016)
Outdoor unit – Air flow rate (max Max.)
27.0 m³/min
Outdoor unit – Sound pressure level (cooling, rated)
51 dB(A)
Outdoor unit – Sound pressure level (heating, rated)
53 dB(A)
Outdoor unit – Dimensions (W x H x D) – Net
230x495x717 mm
Outdoor unit – Dimensions (W x H x D) – Shipping
321x540x836 mm
Outdoor unit – Weight (net)
26.0 kg
Outdoor unit – Weight (shipping)
30.5 kg
Outdoor unit – Maximum fuse size
15 A
Outdoor unit – External colour code
Munsell 9.54Y 8.34/1.31 (RAL 9001)
Outdoor unit – Operating range (cooling)
18 ~ 48 °C DB
Outdoor unit – Operating range (heating)
-5 ~ 24 °C DB
-5 ~ 18 °C WB
Circuit breaker
15 A
Power supply cable
3 x 1.0 (number x mm²)
Power supply unit
Outdoor
Power and communication cable
4 x 0.75 (number x mm²)
Pipes – volume (liquid)
6.35 mm diameter
Pipes