Description
General Specifications
Cooling Capacity (Min ~ Rated ~ Max)
1.77 ~ 8.80 ~ 11.14 kW
6,035 ~ 30,000 ~ 38,000 BTU/h
Heating Capacity (Min ~ Rated ~ Max)
1.47 ~ 8.50 ~ 9.79 kW
5,000 ~ 29,000 ~ 33,400 BTU/h
Power Input – Cooling (Min ~ Rated ~ Max)
610 ~ 2,440 ~ 3,990 W
Power Input – Heating (Min ~ Rated ~ Max)
559 ~ 2,235 ~ 3,990 W
Running Current – Cooling (Min ~ Rated ~ Max)
3.92 ~ 11.20 ~ 17.00 A
Current Operation – Heating (Min ~ Rated ~ Max)
3.68 ~ 10.50 ~ 17.00 A
Energy Efficiency Ratio (EER)
3.61 W/W
12.30 (Btu/h)/W
Seasonal Energy Efficiency Ratio (SEER)
17.54
Coefficient of Performance (COP)
3.80 W/W
12.98 (Btu/h)/W
Power Supply
1, 220, 50 (Φ/V/Hz)
Available Voltage Range
276 ~ 187 V
Power Factor – Cooling
98%
Power Factor – Heating
98%
Dehumidification
2.66 L/h
Indoor Unit – Air Flow Rate (Cooling, Max/High/Medium/Low)
32/25/21/17 m³/min
Indoor Unit – Air Flow Rate (Heating, Max Max/High/Medium/Low)
33/27/23/19 m³/min
Indoor unit – Sound pressure level (cooling, max/high/medium/low)
57/52/47/43/34 dB(A)
Indoor unit – Sound pressure level (heating, max/high/medium/low)
57/52/47/43 dB(A)
Indoor unit – Dimensions (W x H x D) – Net
265x360x1200 mm
Indoor unit – Dimensions (W x H x D) – Shipping
357x455x1280 mm
Indoor unit – Weight (net)
18.5 kg
Indoor unit – Weight (shipped)
22.2 kg
Indoor unit – External colour code
Munsell 7.5BG 10/2 (RAL 9016)
Outdoor Unit – Air Flow Rate (Max)
71 m³/min
Outdoor Unit – Fan Motor Speed (Cooling, Min ~ Max)
190 ~ 850 rpm
Outdoor Unit – Fan Motor Speed (Heating, Min ~ Max)
190 ~ 850 rpm
Outdoor Unit – Sound Pressure Level (Cooling, Rated)
58 dB(A)
Outdoor Unit – Sound Pressure Level (Heating, Rated)
59 dB(A)
Outdoor Unit – Dimensions (W x H x D) – Net
330x832x950 mm
Outdoor Unit – Dimensions (W x H x D) – Shipping
456x908x1130 mm
Outdoor Unit – Weight (Net)
67.1 kg
Outdoor Unit – Weight (Shipping)
72.7 kg
Outdoor Unit – Maximum Fuse Size
25 A
Unit External – External colour code
Munsell 9.54Y 8.34/1.31 (RAL 9001)
Outdoor unit – Operating range (cooling)
18 ~ 54 °C as dry bulb temperature
Outdoor unit – Operating range (heating)
-5 ~ 24 °C as dry bulb temperature
-5 ~ 18 °C as wet bulb temperature
Circuit breaker
25 A
Power supply cable
3 × 2.5 (number × mm²)
Power supply to the unit
Outdoor unit
Power and communication cable
4 × 0.75 (number × mm²)
Pipes – Size (liquid)
9.52ø mm
Pipes – Size (gas)
15.88ø mm
Pipes – Connection method (indoor/outdoor unit)
Flanging
Drain hose size (outside diameter, inside diameter)
20, 15 mm
Between indoor and outdoor unit – Pipe length (Min./Standard/Max.)
3/7.5/30 m
Between indoor and outdoor units – Pipe length (without charge)
3.5 m
Between indoor and outdoor units – Maximum height difference
25 m
Between indoor and outdoor units – Thermal insulation of connection pipes
Both liquid and gas pipes
Refrigerant – Type
R410A
Refrigerant – Precharge
2400 g
Refrigerant – Additional charge
30 g/m
Refrigerant – Control
Electronic expansion valve
Refrigerant – Global warming potential
2087.5
Refrigerant – t-CO₂ eq
5.01
Product type
Big